M200 Liquid handling workstation
항상 혁신적인 제품 개발에 힘을 쓰고 있으며, 첨단 과학장비에 다가가려 연구하고 있습니다. M200/M20 Liquid Hanlding workstation은 경제적인 가격에 매우 손쉽게 대량의 작업이 가능케 만든 제품입니다.
Liquid Handling Workstation은 2개의 제품군이 있습니다.
0.5~20 μL (M20)과 5~200 μL (M200), 이 제품들은 96-well plate와 384-well plate간의 transfer, orifice cleaning, dilution 및 ELISA / EIA 등에 사용될 수 있습니다.

Descriptions
M200은 ELISA, cell analysis, QPCR과 protein crystallization을 매우 손쉽게 할 수 있게 해줍니다. 해당 제품은 매우 인체공학적으로 디자인 되어있을 뿐만 아니라, 별도의 교육 없이도 손쉽게 작업이 가능합니다.
- Reduce pipetting steps effectively
Our workstations reduce pipetting steps effectively, which takes less than 6 seconds to complete one time of 96-well plate pipetting by hand, and only 4 steps for 384-well plate with 2 times within 1 minute.
- Increase your data accuracy
These pipetting stations can start or stop the enzymatic reaction or cell experiments at the same time in the 96-well plate. The 96-well plate is simultaneously pipetting, which greatly improves the quality of experiment data such as ELISA, and also eliminates the difference between well to well. It improves the reproducibility from well to well and from plate to plate, and never skips or repeats pipetting.
- Easy and safe to use
Liquid Handlers provide a ultra-fast pipetting with no programming, no plug-in and no training.
Key Futures
- Volume range 5 – 200 μl.
- A perfect choice for experiments such as ELISA with a volume range of 5-200μL.
- High reproducibility ensures the accurate experiment data.
- Simple to use with no programming, no plug-in and no training.
- Compact size make it suitable for use in any laboratory.
- Four SBS footprint operating positions.
Application
Clearly observe and cut the nucleic acid in the stained gel, replacing the traditional ultraviolet transmission instrument.
Specification | Description |
Cell culture Device | Set up motherboard-sub-board in a few seconds |
Cell analysis | Use accurate reagents to split cells by pipetting up to 96 samples |
PCR & QPCR | Pipetting the PCR/QPCR reagent to a 96-well plate |
Enzyme-linked immunosorbent assay | Add reagents and start/stop reactions Simultaneously in all 96 wells |
Protein crystallography | Quickly allocate buffers to orifice plates for suspension drop method |
Drug Compound Screening | Quickly add sensors, biomolecules and compounds to 96/384-well plates |
Sequencing of sample preparation | Simultaneous allocate buffers, enzymes and nucleic acids |
Sorting the sample clean | Accelerate precipitation and purification via 96-channel pipetting |
Standard enzyme Analysis | Accurately pipetting of enzymes, buffers and matrices to orifice plates |
Specifications
Description | M200 |
Range | 5μL-200μL |
SLAS/ANSI Position | Four |
Product Size(L×W×H) | 320×450×390mm |
Weight | 13.5kg |
Volume increment | 0.2μL |
Pipetting Technology | Air-cushion |
Power Requirements | N/A |
Accuracy | ± 1.2% |
Precision | ≤0.8% |
The accuracy and precision of our products are tested according to internal SOP . | |
Conditions of testing are as follows: | |
Location: QA Lab | |
Ambient Temperature: 15℃~24℃ | |
The Relative humidity: 55%~75%, incondensable | |
The Air Pressure: 860hPa~1060hPa | |
Tested Liquid: 20℃ distilled water | |
Pipetting tips: Ultra low retention pipette tips | |
Pipetting type: Forward technique | |
Replace the pipetting tips in each test. |
Frequent Asked Questions (FAQ)
- Q1: The liquid handling workstations은 plate cleaing에 적용할 수 있는지. ELISA plate washer가 포함되어 있나요??
아닙니다. plate washer가 아니며, 포함되어있지 않습니다.
- Q2: 기기 내 포함되어 있는 것은?
pipette head와 base만 포함되어 있습니다.
- Q3: 일반 liquid handler처럼 전용팁이나 로보틱팁을 사용하나요? 일반팁 사용이 가능한가요?
기존 사용하는 팁 사용이 가능합니다. 거의 대부분의 팁들이 사용 가능합니다. 다만 팁랙 베이스는 genfollower의 E type tip에 최적화 되어 있어서, GFK의 팁을 사용하기를 권장합니다. 다른 팁케이스 사용시 별도의 베이스가 필요합니다.
- Q4: 보증(warranty) 기간은?
구입 후 1년입니다. 고객에 의한 파손을 제외하고 보상기간내에는 무상 수리 및 교체 가능합니다.
- Q6: 전기가 필요한 제품인가요?
아닙니다. 본 제품은 어떠한 전원도 연결할 필요 없이 파이펫처럼 손쉽게 사용 가능한 제품입니다.