SMB-MH Dry Bath
(Heating, Shaking)
This product is an advanced microcomputer-controlled dry bath incubator with a wide selection of metal blocks suitable for various test tubes, which can be widely used for sample preservation, enzymes preservation and reaction, pre-denaturation of DNA amplification and electrophoresis, serum coagulation, etc.
Descriptions
1. Temperature control range: 0 ℃ -100 ℃
2. Timing range: 1 min-99 h 59 min
3. Heating time: (room temperature rises to 100°C) ≤ 15 min
4. Temperature control accuracy: ≤±0.5℃
5. Temperature uniformity: ≤±0.5℃
6. The oscillation speed is accurate and the fluctuation is small
7. Fast heating speed, uniform heating and precise temperature control
8. Replaceable modules, suitable for various centrifuge tubes
Basic Parameters
|
Model |
SMB-MH |
|
Standard Module |
A: 1.5 mL X 35 |
|
Optional Modules |
B: 0.5 mL X 54 |
|
C: 0.2 mL X 96 |
|
|
D: 2.0 mL X 35 |
|
|
E: 0.2 mL X 32+1.5 mL X 25 |
|
|
F: 5 mL X 24 |
|
|
G: 15 mL X 12 (high lid) |
|
|
H: 50 mL X 6 (high lid) |
|
|
I: 0.2 mL X 96 ( ELISA plate) |
|
|
J: 0.2 mL X 32+0.5 mL X 10+1.5 mL X 15 |
|
|
Dimensions (mm) |
175x278x227 |
|
Weight (kg) |
9.6 |
Note: Metal modules can be customized according to user requirements, if you need customized modules, please contact the supplier.
Normal Working Conditions:
Ambient temperature: 10°C~ 30°C
Relative humidity: ≤ 70%
Input power: AC100 ~ 240
AC frequency: 50 Hz/60 Hz
Output power: 24 V 6.25 A 150 W
Note: Before using the instrument, please confirm whether the working conditions meet the above requirements
Transportation And Storage Conditions:
Ambient temperature: -20°C ~ +55°C
Relative humidity: <80%
Specifications
|
Cat. No. |
SMB-C |
SMB-H |
SMB-PC |
SMB-MH |
|
Programming Function |
_ |
_ |
Programmable |
_ |
|
Horizontal Amplitude |
_ |
_ |
_ |
3mm |
|
Speed Range |
_ |
_ |
_ |
200-2000rpm |
|
Temperature Control Range |
0-100℃ |
RT+5℃-100℃ |
0-100℃ |
RT+5℃-100℃ |
|
Temperature Setting Range |
0-100℃ |
RT+5℃-100℃ |
0-100℃ |
RT+5℃-100℃ |
|
Timing Range |
1min- 99h59min |
1min- 99h59min |
1min- 99h59min |
1min- 99h59min |
|
Module Temperature Stability @40-100℃ |
≤±0.5℃ |
≤±0.5℃ |
≤±0.5℃ |
≤±0.5℃ |
|
Module Temperature Uniformity @40℃ |
≤±0.3℃ |
≤±0.3℃ |
≤±0.3℃ |
≤±0.5℃ |
|
Module Temperature Uniformity >@40℃ |
≤±0.5℃ |
≤±0.5℃ |
≤±0.5℃ |
≤±0.5℃ |
|
Temperature Display Accuracy |
0.1℃ |
0.1℃ |
0.1℃ |
0.1℃ |
|
Speed of Rise and Fall |
≤15min(20℃-100℃) |
≤15min(20℃-100℃) |
≤15min(20℃-100℃) |
≤15min(20℃-100℃) |
|
Sample Processing Capacity |
A standard module |
A standard module |
A standard module |
A standard module |
|
Input Power Supply |
AC100V/AC 220V 50Hz/60Hz |
AC100V/AC 220V 50Hz/60Hz |
AC100V/AC 220V 50Hz/60Hz |
AC100V/AC 220V 50Hz/60Hz |
|
Power |
150W |
150W |
150W |
216W |
|
Fuse |
250V/3A |
250V/3A |
250V/3A |
250V/3A |
|
Overall Dimension |
175*278*197mm |
175*278*197mm |
175*278*197mm |
175*278*227mm |
|
Net Weight |
3.3kg |
2.2kg |
3.3kg |
9.6kg |